TM 1-1520-238-23
2-186
2.59.
CPG STATION ACCESS DOOR UPPER HINGE BUTT REMOVAL/INSTALLATION continued
d. Check perimeter of door (9) for weather seal
gaps.
(1) Enter CPG station (para 1.56). Observe all
safety precautions.
(2) Close and latch door (9).
(3) Person on outside of door shine flashlight
around perimeter.
(4) Identify and mark gaps.
(5) If no gaps are visible, go to step g.
(6) If gaps are visible, go to step e. or f. as re-
quired.
e. Adjust door seal (11).
(1) Remove rivets from door bumper (12)
(TM 1-1500-204-23).
(2) Clean seal (11) and mating surface
(para 1.47).
NOTE
Door seal can be adjusted to eliminate
gaps, except in corners.
(3) Position seal (11) and apply sealant. Use
adhesive (item 14, App F).
(4) Install rivets in door bumper (12)
(TM 1-1500-204-23).
f. Apply adhesive to airframe bumpers (13) to
eliminate gaps in corners. Use adhesive
(item 19, App F).
GO TO NEXT PAGE
M04-3619-13
12
13
9
11