TM 1-1520-238-23
2-182
2.59.
CPG STATION ACCESS DOOR UPPER HINGE BUTT REMOVAL/INSTALLATION continued
2.59.6. Alinement
CAUTION
To prevent damage to helicopter, door
cylinder assembly must be secured be-
fore positioning door.
a. Secure door cylinder assembly (5).
(1) Compress cylinder (5) and turn door handle
(6) to latched position to hold cylinder (5).
(2) Install lockwire through lower cylinder bearing
(7) and upper strut bracket (8). Use wire
(item 225, App F).
(3) Cover cylinder (5) and lockwire with tape to
prevent damage to helicopter. Use tape
(item 201, App F).
CAUTION
To prevent damage to rubber door seal,
avoid pinching between door skin and air-
frame.
b. Position CPG station access door (9) in air-
frame (10).
(1) Install hinge pins (11) in undamaged hinge (1)
(if applicable).
(2) Press top of door (9) into airframe (10) to
obtain compression of rubber seal (11).
(3) While holding pressure at top of door (9), en-
gage door handle (6) latch.
(4) Position door (9) to float on seal (11) in open-
ing. Contact between door bumper (12) and
airframe bumper (13) is not acceptable.
GO TO NEXT PAGE
M04-3619-9
7
5
6
8
M04-3619-4
12
13
9
11
1
11
10