TM 1-1520-238-23
2-569
2.154.
CPG FIXED GLARESHIELD REMOVAL/INSTALLATION continued
b. Install right glareshield (1) on panel (2).
(1) Aline right glareshield (1) with panel (2) and
boresight support (14).
NOTE
Electrical lead is installed on second
screw outboard right of boresight sup-
port.
(2) Install seven screws (3), electrical lead (5),
and seven washers (4).
(3) Install two screws (6) and washers (7).
c. Tighten seven screws (3), eight screws (9),
two screws (12), and two screws (6).
d. Inspect (QA).
e. Attach CPG FIRE EMERG panel (para 12.37).
f. Install CPG master caution/warning panel
(para 9.122).
g. Install CPG flood lights electrical harness
(para 9.79).
h. Perform boresight reticle unit (BRU) aline-
ment (TM 9-1230-476-20-1).
END OF TASK
M04-2109-5
6
7
1
14
2
5
3
4
3
4
11
5
M04-2109-8
9
10