TM 1-1520-238-23
2-565
2.153.
CPG GLARESHIELD EXTENSION ASSEMBLY REMOVAL/INSTALLATION continued
2.153.3. Removal
a. Enter pilot and/or CPG station (para 1.56). Ob-
serve all safety precautions.
b. Remove CPG right extension assembly (1)
from right fixed glareshield assembly (2).
(1) Hold spring (3) on guide assembly (4) out of
way.
(2) Insert 6-inch scale between glareshield track
(5) and channel assembly (6) to release lock
(7).
(3) Slide track (5) on extension (1) out of channel
(6) on glareshield (2).
c. Remove CPG left extension assembly (8) from
left fixed glareshield assembly (9).
(1) Hold spring (3) on guide (4) out of way.
(2) Insert 6-inch scale between track (5) and
channel (6) to release lock (7).
(3) Slide track (5) on extension (8) out of channel
(6) on glareshield (9).
2.153.4. Cleaning
a. Wipe removed and attaching parts with a
clean rag.
2.153.5. Inspection
a. Check extensions for cracks. None allowed.
b. Check channel and track for freedom of move-
ment.
c. Check guides on glareshields and extensions
for cracks. None allowed.