TM 1-1520-238-23
2-658.12
Change 2
2.181D. ARMORED PANEL SEAL REMOVAL/INSTALLATION continued
2.181D.4. Inspection
a. Check panel for cracks. None allowed.
b. Check removed and attaching parts for corro-
sion (para 1.49).
2.181D.5. Installation
WARNING
When using heater gun, avoid any
contact with skin. Heat gun touching
bare skin can cause serious burns. If
burns occur, seek immediate medical
aid.
NOTE
If abrasive paper is used, wipe surface
with solvent dampened cloth to re-
move dust.
No pressure is required other than
necessary to ensure adequate contact
to maintain the seal in required posi-
tion.
a. Install seal (1) on armored panel (2).
(1) Wipe rubber surface of seal (1) to remove
soapstone. Use cloth (item 52, App F) damp-
ened with naphtha (item 127, App F).
(2) If panel (2) seal adhesion area (3) is glossy,
abrade with abrasive paper to remove gloss.
Use paper (item 133, App F).
GO TO NEXT PAGE
M04-5139-2
1
2
3