3.29.
REMOTE CONTROL LEVER REMOVAL/INSTALLATION continued
3.29.6. Installation
a. Install lever (1) on actuator (2).
(1) Install pin (10) through two connecting links
(11) and lever (1).
(2) Install two washers (9) and retaining rings (8)
on pin (10).
(3) Install pin (7) through actuator (2) and lever
(1).
(4) Install two washers (6) and retaining rings (5)
on pin (7).
(5) Install two springs (3) on handle (4) and lever
(1).
b. Inspect (QA).
END OF TASK