TM 1-1520-238-23
4-258
Change 1
4.80.
NO. 2 ENGINE REGULATING VALVE REMOVAL/INSTALLATION continued
4.80.4. Cleaning
a. Wipe removed and attaching parts with a
clean rag.
4.80.5. Inspection
a. Check starter flange for cracks. None allowed.
b. Check regulating valve and starter flange for
corrosion (para 1.49).
d. Check regulating valve for loose, missing, or
damaged hardware. None allowed.
e. Check regulator valve for cracked or dented
housings. None allowed.
f. Check regulating valve connector and recep-
tacle for cracks, corrosion, and broken, bent,
or damaged pins (TM 55-1500-323-24).
g. Check regulating valve for stripped or dam-
aged threads. None allowed.
h. Check identification plate for legibility, de-
formation, and security of attachment to
housing.
i. Check solenoid case for damage. None al-
lowed.
d. Check starter connector and receptacle for
cracks, corrosion, and broken, bent, or dam-
aged pins (TM 55-1500-323-24).
4.80.6. Installation
a. Install valve (10) on starter (16).
(1) Position valve (10) between starter (16) and
tube (11).
(2) Install bolt (18) through washer (19), clamp
(20), and valve support (21) into starter (16).
GO TO NEXT PAGE
M04-1013-5
20
18
19
21
16
11
16
10