TM 1-1520-238-23
4-443
4.139.
EMERGENCY POWER CHECK PANEL DISASSEMBLY/ASSEMBLY (AVIM) continued
i. Install eight insulators (17) into component
board (4).
(1) Hand press insulators (17) into component
board (4).
(2) Install eight terminals (19) into insulators (17).
(3) Solder identified wires (18) to terminals (19).
Use soldering iron and solder (item 189,
App F) (TM 55-1500-323-24).
j. Solder two resistors (20) to terminals (19). Use
soldering iron and solder (item 189, App F)
(TM 55-1500-323-24).
k. Install relay (14) on component board (4).
(1) Hand press socket (16) into component
board (4).
(2) Install relay (14) into relay socket (16).
(3) Pin identified wires (15) in socket (16)
(TM 55-1500-323-24).
GO TO NEXT PAGE
M04-3631-7
20
18
17
19
4
ROTATED FOR CLARITY
M04-3631-8
15
1614
4