TM 1-1520-238-23
4-444
4.139.
EMERGENCY POWER CHECK PANEL DISASSEMBLY/ASSEMBLY (AVIM) continued
l. Install receptacle J1 (9) into component board
(4).
(1) Install four screws (12), through receptacle
(9), component board (4), washers (13), and
nuts (11).
(2) Pin identified wires (10) in receptacle (9)
(TM 55-1500-323-24).
m. Install component board (4) on three posts (5).
(1) Install three screws (6) through lockwashers
(7), washers (8), component board (4) into
posts (5).
n. Install panel (1) on panel (2).
(1) Install three screws (3).
o. Inspect (QA).
END OF TASK
M04-3631-9
3
1
2
11
13
12
6
7
4
9
8
10
5