TM 1-1520-238-23
Change 1
4-611
4.174.
NO. 2 ENGINE POWER AVAILABLE SPINDLE AFT CABLE INSTALLATION continued
(4) If ribbon movement is rough or friction load
exceeds 1.5 POUNDS, replace cable.
b. Install cable (2) through firewall plate (3) and
seal retainer (4).
(1) Install end of cable (2) (5) forward through
plate (3) and louver enclosure (6).
(2) Install end of cable (2) located nearest to fire-
seal (5) aft through seal (4).
GO TO NEXT PAGE
M04-1202-3
M04-1202-4
2
3
5
6
M04-1202-10
M04-1202-11
4
2
5