TM 1-1520-238-23
Change 6
5-148.1/(5-148.2 blank)
5.31.
MAIN ROTOR PITCH HOUSING AND BLADE ELECTRICAL LEAD
REMOVAL/INSTALLATION continued
e. Perform electrical bond check on electrical leads (TM 55-1500-323-24).
(1) Bond shall be 1.00 OHM or less. Use multimeter.
f. Lockwire bolt (1) to adjacent bolt (16). Use wire (item 225, App F).
g. Seal electrical lead attaching hardware. Use sealing compound (item 163, App F)
h. Inspect (QA).