TM 1-1520-238-23
7-365
7.94.
UTILITY HYDRAULIC RETURN ACCUMULATOR REMOVAL/INSTALLATION continued
c. Remove tube (1) from utility hydraulic return
accumulator (2).
(1) Place rags under tube (1) to catch hydraulic
fluid spills.
(2) Remove nut (3) from reducer (4).
d. Remove accumulator (2) from bracket (5).
(1) Remove four locknuts (6), washers (7),
screws (8), and washers (9) from two clamps
(10) and bracket (5). Discard locknuts (6).
(2) Remove top halves of two clamps (10).
(3) Remove accumulator (2).
(4) Remove bottom halves of two clamps (10)
and four spacers (11) from bracket (5).
e. Remove union (12) from accumulator (2).
(1) Remove and discard packing (13).
f. Remove reducer (4) from accumulator (2). Use
open end wrench and crowfoot.
(1) Remove and discard packing (14).
7.94.4. Cleaning
a. Wipe removed and attaching parts with a
clean rag.
GO TO NEXT PAGE
M04-3297-3
1
2
3
4
M04-3297-4
8
9
10
10
11
7
6
5
2
M04-3297-10
4
14
2
12
13