TM 1-1520-238-23Change 57-1457.41.COLLECTIVE SERVOCYLINDER REMOVAL – continuedNOTEIf ground cable is installed on helicopter,go to step v. If not, go to step w.v. Remove cable (39) from servocylinder (9).(1) Remove sealant from screw (40), nut (41),washer (42), and clamp (43) (para 1.47).(2) Hold screw (40). Remove nut (41) and wash-er (42).(3) If replacing servocylinder (9), remove clamp(43).WARNINGTo prevent movement of bellcrank andpossible injury, support bellcrank be-fore disconnecting servocylinder. Ifinjury occurs, seek medical aid.w. Remove rod end (44) from bellcrank (45).(1) Remove sealant from attaching hardware(para 1.47).(2) Remove and discard cotter pin (46).(3) Hold bolt (47). Use box wrench.(4) Remove nut (48). Use box wrench.(5) Remove bolt (47) and washer(s) (47.1) ifinstalled.NOTEDo not remove nylon washer unless it isloose or excessively worn.(6) Remove bushing (49) and nylon washer (50)(if necessary).x. Remove servocylinder (9) from bellcrank (45).GO TO NEXT PAGEM04-794-1541424093943M04-794-11A484645474447.1M04-794-12A5094549