PITOT STATIC TESTER INSTALLATION/REMOVAL
8.36.1. Description
This task covers:
Installation. Testing. Removal.
8.36.2. Initial Setup
Tools:
Electrical tool kit (item 378, App H)
Static port adapter (item 8, App H)
Screws (item 277, App H)
Pitot and static systems tester (item 350, App H)
Materials/Parts:
Packing
Personnel Required:
68X
Armament/Electrical System Repairer
68X3F
Armament/Electrical System Repairer/
Technical Inspector
References:
TM 1-1500-204-23
Equipment Conditions:
Ref
Condition
1.57
Helicopter safed
NOTE
This task is typical for the right and left
pitot static system
8.36.3. Installation
a. Attach static port adapter (1) to helicopter
static port (2).
(1) Remove two screws (3) from port (2) at the 3
and 9 oclock position.
(2) Ensure packing (4) is in groove on matching
surface of adapter (1). Use static port
adapter.
(3) Aline adapter (1) with port (2).
(4) Install two screws (5). Use screws.
GO TO NEXT PAGE
M04-3635-1
1
3
5
5
3
2
M04-3635-2
4