TM 1-1520-238-23
8-96
8.37.
RIGHT OR LEFT WING PITOT TUBE REMOVAL/INSTALLATION continued
(3) Pull pitot tube (1) from housing (2) until pitot
line fitting (4) is clear of housing (2).
(4) Detach connector P1010 (right wing)/P208
(left wing) (5) from receptacle HR8 (right
wing)/HR6 (left wing) (6).
(5) Remove pitot line fitting (7) from pitot tube
fitting (8).
8.37.4. Installation
a. Install tube (1) in housing (2).
(1) Connect fitting (7) to fitting (8).
(2) Attach connector P1010 (right wing)/P208
(left wing) (5) to receptacle HR8 (right
wing)/HR6 (left wing) (6).
(3) Gently push tube (1) into housing (2).
(4) Install three screws (3).
b. Inspect (QA).
c. Perform flight instruments maintenance op-
erational check (TM 1-1520-238-T).
d. Install pitot head protective cover (para 1.59).
END OF TASK
M04-169-5
2
4
1
M04-169-6
7
8
5
6
M04-169-7
3
2
1