TM 1-1520-238-23
8-109
8.40.
PITOT STATIC SYSTEM TUBING SWAGELOK FITTING REPLACEMENT continued
8.40.5. Installation
a. Install fitting (1) on tubing (2).
(1) Hold fitting (1).
(2) Insert tubing (2) into fitting (1).
(3) Ensure tubing (2) rests firmly against shoul-
der of fitting assembly (1).
(4) Hold tubing and turn nut (3) clockwise ensur-
ing tubing cannot be rotated or moved axially.
(5) Mark nut (3) and the tubing (2) on center line
of tubing (2). From marked position, rotate
nut (3) in clockwise direction. 1 1/4 turns for
pitot system tube and 3/4 turn for static sys-
tem tube.
b. Inspect (QA).
c. Perform
pitot
static
system
test
(TM 1-1500-204-23).
d. Reapply system identification tape if removed
(TM 1-1500-204-23). Use marker (item 123,
App F).
END OF TASK
3
1
2
M04-3733-3
3
1
2
M04-3733-4
1
3
2
1
3
2
M04-3733-5