TM 1-1520-238-23
8-104
Change 3
8.39.
PITOT STATIC SYSTEM TUBING SPLICE REPLACEMENT continued
(4) Crimp 0.50 INCH end of tubing (2) for installa-
tion of adapter (4).
(5) Slide adapter (4) 0.42 INCH in tubing (2).
(6) Shrink splice (1) down over tubing (2) and
adapter (4). Move heater or tubing slowly to
ensure proper shrinkage of sleeving. Use
heater.
(7) Remove all excess adhesive. Use methyl
ethyl ketone (item 124, App F) and cloth
(item 52, App F).
(8) Allow 24 HOUR cure time.
b. Install splice (1) over convoluted tubing (2)
and pitot tubing (5).
(1) Cut one 1.0 INCH splice from sleeving instal-
lation. Use insulation sleeving (item 104,
App F).
(2) Abrade end of tube (5) 0.50 INCH. Use cloth
(item 48, App F).
(3) Apply adhesive to each end of tubing (2) and
(5) 0.50 INCH. Fill in all valleys of tubing (2).
Use adhesive (item 9, App F).
(4) Slide splice (1) over tubing (2).
(5) Hold tubing (2) and tubing (5) together.
(6) Slide splice (1) over both ends of tubing so
that there is 0.50 INCH of splice over each
tube.
(7) Shrink splice (1) down over tubing (2) and
tubing (5). Move heater or tubing slowly to
ensure proper shrinkage of sleeving. Use
protective gloves and heater.
(8) Remove all excess adhesive. Use methyl
ethyl ketone (item 124, App F) and cloth
(item 52, App F).
GO TO NEXT PAGE
M04-3732-7
1
4
2
M04-3732-3
2
1
5
0.50
1.00