TM 1-1520-238-23
8-123
8.48.
PILOT/CPG STABILATOR POSITION INDICATOR REMOVAL/INSTALLATION
8.48.1. Description
This task covers:
Removal. Cleaning. Inspection. Installation.
8.48.2. Initial Setup
Tools:
Electrical tool kit (item 378, App H)
Personnel Required:
68X
Armament/Electrical System Repairer
68X3F
Armament/Electrical System Repairer/
Technical Inspector
References:
TM 1-1520-238-T
Equipment Conditions:
Ref
Condition
1.57
Helicopter safed
8.48.3. Removal
a. Enter pilot/CPG station (para 1.56). Observe
all safety precautions.
b. On pilot aft circuit breaker panel, open STAB
circuit breakers AUTO AC, AUTO DC, MAN
DC, and MAN AC.
c. On pilot/CPG INTR LT panel, rotate INST con-
trol to OFF.
GO TO NEXT PAGE
PILOT STATION
M04-2918-1
M04-2918-2
CPG STATION