TM 1-1520-238-23
8-124
8.48.
PILOT/CPG STABILATOR POSITION INDICATOR REMOVAL/INSTALLATION continued
d. Remove stabilator position indicator (1) from
instrument panel (2).
(1) Remove four screws (3).
(2) Pull indicator (1) clear of panel (2).
(3) Detach connector P981 (pilot)/P982 (CPG)
(4) from receptacle (M51)J1 (pilot)/(M52)J1
(CPG) (5).
8.48.4. Cleaning
a. Wipe mounting area and indicator with a clean
rag.
8.48.5. Inspection
a. Check indicator and panel mounting area for
cracks, nicks, and dents (para 8.43).
b. Check indicator and panel screw holes for
stripped or damaged threads (para 8.43).
8.48.6. Installation
a. Install indicator (1) in panel (2).
(1) Attach connector P981 (pilot)/P982 (CPG) (4)
to receptacle (M51)J1 (pilot)/(M52)J1 (CPG)
(5).
(2) Aline indicator (1) with screw holes in panel
(2).
(3) Install four screws (3).
b. Inspect (QA).
c. Perform stabilator operational maintenance
check (TM 1-1520-238-T).
END OF TASK