TM 1-1520-238-23
Change 3 9-9
SECTION I. POWER GENERATION AND DISTRIBUTION COMPONENTS
MAINTENANCE
9.1.
POWER GENERATION AND DISTRIBUTION COMPONENTS INSPECTION
9.1.1. Description
This task covers:
Inspection.
9.1.2. Initial Setup
Tools:
Electrical tool kit (item 378, App H)
0.0 - 10.0-pound weighing scale (item 272, App H)
Inspection insert gauge (figure D-452, App D)
Materials/Parts:
Wire (item 222, App F)
Personnel Required:
68X
Armament/Electrical System Repairer
68X3F
Armament/Electrical System Repairer/
Technical Inspector
References:
TM 1-1500-204-23
TM 55-1500-323-24
Equipment Conditions:
Ref
Condition
1.57
Helicopter safed
9.1.3. Inspection
a. Check components for damage and loose mounting.
b. Check panel mounting area for cracks, nicks, and damaged threads. None allowed.
c. Check for loose, missing, or damaged mounting hardware (TM 1-1500-204-23). Replace as necessary.
d. Check nutplates for loose rivets and stripped or damaged threads (TM 1-1500-204-23).
e. Check wire bundles for chafing, loose mounting, and broken or missing wire ties (TM 55-1500-323-24).
f. Check wiring for wear, cuts, breaks, and cracked, broken, or burned insulation (TM 55-1500-323-24).
g. Check wiring and electronic components for cracked, loose, or cold solder joints (TM 55-1500-323-24).
h. Check wire terminals for deformation and loose mounting hardware (TM 55-1500-323-24).
GO TO NEXT PAGE