TM 1-1520-238-23
Change 6 9-96.3
9.26.
AC GENERATOR NO. 1 REMOVAL/INSTALLATION continued
i. Install clamp block bracket (13.5) on genera-
tor (2). Torque clamp retaining nut (13.8) to 45
INCH-POUNDS.
(1) Position clamp block bracket (13.5) on gener-
ator (2).
(2) Coat threads of screw (13.6). Use corrosion
preventive compound (item 62, App F).
(3) Install screw (13.6) through bracket (13.5)
into generator (2).
(4) Lockwire screw (13.6). Use wire (item 226,
App F).
(5) Position clamp (13.7) on bracket (13.5) and
around generator (2).
(6) Torque clamp retaining nut (13.8) to 45 INCH-
POUNDS.
CAUTION
To prevent possible equipment dam-
age, terminal wires must be recon-
nected at exact stud positions
identified during generator removal.
Over tightening of terminal studs dur-
ing terminal lug installation can cause
cracking and shorting of the phenolic
insulator.
j. Install three wires (6) and wire harness (13.1)
on bottom half of clamp block (13.2).
(1) Install three wires (6) and wire harness (13.1)
on bottom half of clamp block (13.2).
(2) Aline top half of clamp block (13.2) with bot-
tom half of clamp block (13.2).
(3) Install two screws (13.3) and two washers
(13.4).
GO TO NEXT PAGE