TM 1-1520-238-23
Change 6 9-101
9.27.
AC GENERATOR NO. 2 REMOVAL/INSTALLATION continued
CAUTION
Hold generator while it is on the re-
moval/installation tool to prevent it
from sliding back against the drive
spline adaptor.
Use extreme care when removing
generator to avoid damage to direc-
tional control rod and power cables.
Dropping generator or striking genera-
tor spline will cause internal bearing
damage resulting in premature failure.
NOTE
When removing generator, ensure that
drive spline adapter stays in transmis-
sion. If adapter comes out, replace with
new adapter.
k. Remove generator (2) from drive spline adapt-
er (16) in transmission (17).
9.27.4. Cleaning
a. Wipe QAA and generator mounting area with a
clean rag.
9.27.5. Inspection
a. Check for loose or missing hardware. None
allowed.
b. Check removed and attaching parts for dam-
age (para 9.1).
c. Check removed and attaching parts for corro-
sion (para 1.49).
d. Check generator and QAA for damage,
cracks, distortion, or discoloration. None al-
lowed.
e. Check generator for corrosion (para 1.49).
GO TO NEXT PAGE