TM 1-1520-238-23
9-152
9.43.
CPG CIRCUIT BREAKER PANEL NO. 1 REMOVAL/INSTALLATION continued
9.43.6. Installation
a. Attach connectors P769 (7), P766 (6), P768 (5),
and P767 (4) to panel (1).
(1) Attach connector P769 (7) to receptacle
(A77)J4 (11).
(2) Attach connector P766 (6) to receptacle
(A77)J1 (10).
(3) Attach connector P768 (5) to receptacle
(A77)J3 (9).
(4) Attach connector P767 (4) to receptacle
(A77)J2 (8).
b. Inspect (QA).
c. Install panel (1) on console (2).
(1) Position panel (1) on console (2).
(2) Lock six turn fasteners (3).
d. Perform
electrical
bond
check
(TM 55-1500-323-24).
(1) Bond shall be 0.0025 OHM or less. Use
ohmmeter.
e. Inspect (QA).
f. Refer to circuit breaker reference list to per-
form appropriate maintenance operational
check (TM 1-1520-238-T).
END OF TASK
M04-1370-6
1
7
11
5
9
8
10
6
4
M04-1370-7
1
3
2