TM 1-1520-238-23
9-176
9.51.
PILOT INSTRUMENT PANEL MATRIX REMOVAL/INSTALLATION continued
e. Attach 13 connectors to left end of matrix (1).
(1) Attach connector P435 (42) to receptacle J7
(43). Use socket head key set.
(2) Attach connector P467 (40) to receptacle J5
(41). Use socket head key set.
(3) Attach connector P409 (38) to receptacle J4
(39). Use socket head key set.
(4) Attach connector P405 (36) to receptacle J3
(37). Use socket head key set.
(5) Attach connector P479 (34) to receptacle J11
(35). Use socket head key set.
(6) Attach connector P469 (32) to receptacle J2
(33). Use socket head key set.
(7) Attach connector P465 (30) to receptacle J12
(31). Use socket head key set.
(8) Attach connector P487 (28) to receptacle J9
(29). Use socket head key set.
(9) Attach connector P481 (26) to receptacle J13
(27). Use socket head key set.
(10) Attach connector P413 (24) to receptacle J10
(25). Use socket head key set.
(11) Attach connector P473 (22) to receptacle J6
(23). Use socket head key set.
(12) Attach connector P471 (20) to receptacle J1
(21). Use socket head key set.
(13) Attach connector P477 (18) to receptacle J8
(19).
GO TO NEXT PAGE
M04-3684-9
34
36
38
40
42
35
37
39
41
43
M04-3684-10
20
22
24
26
28
30
32
18
19
21
23
25
27
29
31
33