TM 1-1520-238-23
9-458
9.122.
PILOT OR CPG MASTER CAUTION/WARNING PANEL REMOVAL/INSTALLATION
9.122.1. Description
This task covers:
Removal. Cleaning. Inspection. Installation.
9.122.2. Initial Setup
Tools:
Electrical tool kit (item 378, App H)
Ohmmeter (item 218, App H)
Personnel Required:
68X
Armament/Electrical System Repairer
68X3F
Armament/Electrical System Repairer/
Technical Inspector
References:
TM 1-1520-238-T
TM 55-1500-323-24
Equipment Conditions:
Ref
Condition
1.57
Helicopter safed
NOTE
This task is typical for pilot or CPG mas-
ter caution/warning panel.
9.122.3. Removal
a. Enter pilot or CPG station (para 1.56). Observe
all safety precautions.
b. Identify master caution panel (pilot or CPG) to
be removed.
c. On pilot center circuit breaker panel, open LT
CAUT circuit breaker.
d. On CPG circuit breaker panel No. 1, open EM-
ERG BATT CAUT circuit breaker.
GO TO NEXT PAGE
CPG STATION
PILOT STATION
M04-1377-1