TM 1-1520-238-23
9-457
9.121.
CPG CAUTION/WARNING PANEL FIXED WIRE RESISTOR REPLACEMENT (AVIM) continued
9.121.6. Installation
WARNING
Soldering iron can cause severe
burns to personnel and start fires.
Observe all safety precautions when
using soldering iron. If injury occurs,
seek medical aid.
a. Install resistor (1) on bracket (2).
(1) Position new resistor (1) on bracket (2)
(TM 55-1500-323-24).
(2) Install two screws (7) through resistor (1)
flanges and bracket (2).
(3) Install two nuts (8) and lockwashers (9) on
screws (7).
(4) Solder right lead (5) to jumper (6). Use
soldering iron and solder (item 189, App F)
(TM 55-1500-323-24).
(5) Solder left lead (3) to wire (4). Use soldering
iron
and
solder
(item 189, App F)
(TM 55-1500-323-24).
b. Inspect (QA).
c. Install CPG caution/warning panel bottom
cover (para 9.116).
d. Install pilot CPG caution/warning panel circuit
cards (A157)A1, (A157)A2, (A157)A3,
(A157)A4, and (A157)A5 (para 9.115).
e. Perform appropriate test. Electronic Equipment
Test Facility (E.E.T.F.) (TM 11-6625-3085-30).
END OF TASK
M04-4226-3
1
3
4
5
6
7
8
9
2
VIEW