PILOT OR CPG MASTER CAUTION/WARNING PANEL REMOVAL/INSTALLATION continued
9.122.6. Installation
a. Install panel (5) on glareshield (6).
(1) Position panel (5) on glareshield (6).
(2) Lock four quarter turn fasteners (7).
b. Attach to connector J164 (pilot) or J166 (CPG)
(1) to receptacle P1 (2).
(1) Tighten two captive screws (3).
c. Perform
electrical
bond
check
(TM 55-1500-323-24).
(1) Bond shall be 0.0025 OHM or less. Use
ohmmeter.
d. Install tiewrap (4).
e. Inspect (QA).
f. Perform pilot or CPG caution and warning
system maintenance operational check
(TM 1-1520-238-T).
END OF TASK
1
23
6
M04-1377-3
4
7
5