TM 1-1520-238-23
9-562
9.147.
PILOT EMERGENCY HYDRAULIC SWITCH REMOVAL/INSTALLATION continued
d. Remove pilot EMER HYD switch (3).
(1) Remove nut (4), lockwasher (5), and lockring
(6).
e. Detach wires (7) from switch (3).
(1) Identify wires (7).
(2) Remove two screws (8), lockwashers (9), and
terminal lugs (10).
9.147.4. Cleaning
a. Clean switch mounting surface (para 1.47).
9.147.5. Inspection
a. Check removed and attaching parts for dam-
age (para 9.126).
b. Check wires and terminals for wear, cracks,
and cuts (para 9.126).
c. Check removed and attaching parts for corro-
sion (para 1.49).
9.147.6. Installation
a. Attach identified wires (7) to switch (3).
(1) Install two terminal lugs (10), lockwashers
(9), and screws (8).
b. Install pilot EMER HYD switch (3) in panel (12).
(1) Position switch (3) in hole (11) so that tab (13)
on lockring (6) seats in locator hole (14).
(2) Install lockwasher (5) and nut (4).
c. Inspect (QA).
GO TO NEXT PAGE
910
7
7
6
5
4
3
8
M04-1301-3
ROTATED
9
10
7
13
5
4
3
8
M04-1301-4
12
6
11
14