TM 1-1520-238-23
10-27
10.6.
FORWARD FUEL CELL AFT FUEL QUANTITY TRANSMITTER
REMOVAL/INSTALLATION continued
c. Detach lead (15) and ground lead (16) from
low level sensor (17).
(1) Remove screw (18) and orange lead (15)
from sensor (17).
(2) Remove screw (19) and yellow lead (16) from
sensor (17).
(3) Loosen screw (20).
(4) Remove orange lead (15) and yellow lead
(16) from retainer (21).
d. Remove clamp (22) from transmitter (3).
(1) Remove nut (23), washer (24), screw (25),
and clamp (22) from clamp (26).
e. Remove two bolts (27) and washers (28) from
lower mounting flange (29).
f. Remove transmitter (3) from pressure relief
valve (30).
(1) Hold two upper mounting bolts (31).
(2) Remove two nuts (32) and washers (33).
(3) Remove two bolts (31) and washers (34) from
mounting bracket (35).
GO TO NEXT PAGE
M04-326-4
22
21
16
19
18
17
3
15
20
25
26
24
23
M04-326-5
27
28
29
M04-326-6
30
31
34
35
3
33
32