TM 1-1520-238-23
10-38
Change 2
10.8.
FORWARD FUEL CELL AFT ACCESS PANEL AND AFT COVER
REMOVAL/INSTALLATION continued
10.8.3. Removal
CAUTION
Jet fuel will cause external surface of
fuel cell to swell, delaminate, and leak
if allowed to contact the fuel cell more
than 72 HOURS. Keep jet fuel away
from the outside of fuel cells.
Store fuel quantity transmitter wire
harness in a location or container that
will prevent damage to harness, if har-
ness must be temporarily removed to
service fuel cell.
NOTE
Leave clamps attached to wire harness to
facilitate alinement of mount holes.
a. Remove forward fuel cell aft access panel (1).
(1) Remove eight screws (2), washers (3), and
clamps (4).
(2) Remove five screws (5), washers (6), and
clamp brackets (7).
(3) Stow wire harness (8).
(4) Remove remaining 46 screws (9) and wash-
ers (10).
(5) Remove panel (1). Second person to assist.
GO TO NEXT PAGE
M04-574-7
1
8
2
3
4
5
6
7
9
10
8