TM 1-1520-238-23
10-65
10.14.
FORWARD FUEL CELL FUEL SHUTOFF VALVE REMOVAL/INSTALLATION continued
CAUTION
Jet fuel will cause external surface of fuel
cell to swell, delaminate, and leak if al-
lowed to contact the fuel cell more than
72 HOURS. Keep jet fuel away from the
outside of fuel cells.
c. Remove refueling hose (1) from forward fuel
cell fuel shutoff valve (2).
(1) Remove four bolts (3) and washers (4).
(2) Remove and discard gasket (5).
d. Remove pilot valve hose (6) from valve (2).
(1) Hold nipple (7).
(2) Remove hose nut (8).
e. Identify and disconnect electrical leads (9)
and (10) from valve (2).
(1) Remove screw (11), washer (12), and black
lead (9) from valve (2).
(2) Remove nut (13) and green lead (10) from
stud (14).
f. Remove valve (2) from mounting pad.
(1) Remove three bolts (15) and washers (16).
GO TO NEXT PAGE
M04-328-2
4
6
8
7
2
1
5
M04-328-9
3
2
14
15
16
13
10
9
12
11
BLACK
MOUNTING
PAD
M04-328-12
GREEN