TM 1-1520-238-23
10-244
10.49.
AFT FUEL CELL REMOVAL continued
NOTE
Steps h. thru o. install six covers and one
plug. To install covers, use bolts and
washers that attached parts removed
from fuel cell.
h. Install plug (25) in drain valve fitting (26).
i. Install cover plate (27) on pad (8).
(1) Install six bolts (28) and washers (29).
j. Install cover plate (30) on pad (2) inside fuel
cell (1).
(1) Install six bolts (31) and washers (32).
k. Install cover plate (33) from inside fuel cell (1)
on vent tube adapter mounting pad (11).
(1) Install six bolts (34) and washers (35).
GO TO NEXT PAGE
M04-1914-16
26
25
8
29
28
27
M04-1914-14
M04-1914-40
2
1
31
32
30
1
11
33
M04-1914-21
35
34