TM 1-1520-238-23
10-278
Change 2
10.56.
PILOT FUEL PANEL CROSSFEED SWITCH REPLACEMENT (AVIM) continued
10.56.3. Removal
a. Remove bracket (1) from fuel panel (2).
(1) Remove three screws (3) from top front of
panel (2).
(2) Remove two screws (4), lockwashers (5), and
flat washers (6).
(3) Move bracket (1) gently to gain access to
switches.
WARNING
Soldering iron can cause severe
burns to personnel and start fires.
Observe all safety precautions when
using soldering iron. If injury occurs,
seek medical aid.
NOTE
Perform step b only if wires must be de-
soldered.
b. Desolder nine wires (7) from fuel crossfeed
switch (8).
(1) Identify nine wires (7).
(2) Desolder nine wires (7) from switch (8). Use
soldering iron (TM 55-1500-323-24).
GO TO NEXT PAGE
M04-3360-2A
456
1
3
2
456
1
3
2
7
8
M04-3360-3