TM 1-1520-238-23
10-302
10.64.
CPG FUEL PANEL TRANSFER SWITCH REPLACEMENT (AVIM) continued
10.64.3. Removal
a. Detach connector (1).
(1) Remove two screws (2), nuts (3), and wash-
ers (4) that hold connector (1) to mounting
bracket (5).
WARNING
Soldering iron can cause severe
burns to personnel and start fires.
Observe all safety precautions when
using soldering iron. If injury occurs,
seek medical aid.
b. Desolder six wires (6) from CPG fuel transfer
switch (7).
(1) Identify six wires (6).
(2) Desolder six wires (6) from switch (7). Use
soldering iron (TM 55-1500-323-24).
c. Remove switch (7) from support panel (8).
(1) Remove nut (9).
(2) Remove switch (7), lockwasher (10), and key
washer (11) from back of panel (8).
10.64.4. Cleaning
a. Clean removed and attaching parts and sur-
faces (para 1.47).