CPG FUEL PANEL TRANSFER SWITCH REPLACEMENT (AVIM) continued
10.64.5. Inspection
a. Check wires for damaged connections, cuts,
and chafing (para 10.1).
b. Check panel for cracks and damaged hard-
ware. None allowed.
10.64.6. Installation
a. Install switch (7) on panel (8).
(1) Insert switch (7) through lockwasher (10), key
washer (11), and panel (8) so that tab (12)
seats in locating hole (13).
(2) Adjust length of switch (7) through panel (8).
Use adjustment nut (14).
(3) Install nut (9).
WARNING
Soldering iron can cause severe
burns to personnel and start fires. Ob-
serve all safety precautions when us-
ing soldering iron. If injury occurs,
seek medical aid.
b. Solder six identified wires (6) to switch (7).
(1) Solder six wires (6) to terminals (15) on
switch (7). Use solder (item 189, App F) and
soldering iron (TM 55-1500-323-24).
c. Perform continuity test on six wires (6). Use
multimeter (TM 55-1500-323-24).