TM 1-1520-238-23
10-530
10.126.
NITROGEN INERTING UNIT (NIU) CONDITIONED AIR OUTLET HOSE
REMOVAL/INSTALLATION continued
d. Remove NIU cooling air outlet hose (1) in am-
munition bay.
(1) Loosen screw of clamp (2). Remove hose (1)
from NIU port (3).
(2) Remove screw (4), washer (5), and support
clamp (6) from support bracket (7).
(3) Loosen screw of clamp (8).
(4) Remove hose (1) from vent (9).
GO TO NEXT PAGE
M04-2979-2
M04-2979-3
3
1
2
M04-2979-4
6
5
4
7
M04-2979-5
8
1
9