NITROGEN INERTING UNIT (NIU) REMOVAL/INSTALLATION continued
(9) Slide clamp (5) over free end of hose (4).
(10) Place end of hose (4) over vent (6).
(11) Slide clamp (5) into position to secure hose
(4) to vent (6). Tighten screw of clamp (5).
f. Attach connector P1085 (1) to receptacle
(A146)J1 (2) of NIU (3).
g. Inspect (QA).
h. Perform fuel system priming operation (para
1.23).
i. Perform nitrogen inerting system mainte-
nance operational check (TM 1-1520-238-T).
j. Install ammunition storage magazine
(TM 9-1090-208-23).
k. Install access panel R200 (para 2.2).
END OF TASK