TM 1-1520-238-23
11-172
Change 2
11.33.
CPG COLLECTIVE STICK BUCS SELECT TRIGGER GRIP SWITCH REPLACEMENT continued
11.33.3. Removal
a. Remove switch mounting plate (1) from col-
lective grip (2).
(1) Remove three screws (3).
WARNING
Soldering iron can cause severe
burns to personnel and start fires.
Observe all safety precautions when
using soldering iron. If injury occurs,
seek medical aid.
b. Remove trigger grip switch (4) from grip (2).
(1) Identify
and
desolder
wires
(5)
(TM 55-1500-323-24). Use soldering iron.
(2) Remove grip control pin (6).
(3) Remove spring (7), trigger guard (8), and trig-
ger (9).
(4) Remove switch (4) from grip (2).
11.33.4. Cleaning
a. Clean removed and attaching parts (para
1.47).
11.33.5. Inspection
a. Check for cracked and broken wires. None al-
lowed.
b. Check removed and attaching parts for
cracks. None allowed.
c. Check removed and attaching parts for dam-
age (para 11.5).