TM 1-1520-238-23
Change 2
11-175
11.34.
COLLECTIVE STICK SWITCH AND BRACKET ASSEMBLY REMOVAL/INSTALLATION
11.34.1. Description
This task covers:
Removal. Cleaning. Inspection. Installation.
11.34.2. Initial Setup
Tools:
Electrical tool kit (item 378, App H)
Light duty laboratory apron (item 27, App H)
Heat protective gloves (item 155, App H)
Multimeter (item 215, App H)
Adjustable air filtering respirator (item 262, App H)
5-watt electric soldering iron (item 333, App H)
Materials/Parts:
Solder (item 189, App F)
Wire (item 220, App F)
Personnel Required:
68X
Armament/Electrical System Repairer
68X3F
Armament/Electrical System Repairer/
Technical Inspector
References:
TM 55-1500-323-24
Equipment Conditions:
Ref
Condition
1.57
Helicopter safed
11.24
Collective stick grip assembly removed
NOTE
This task is typical for pilot or CPG collec-
tive stick.
11.34.3. Removal
a. Remove bottom control grip (1) from top con-
trol grip (2).
(1) Remove lockwire from grip (1) and grip con-
trol collar (3).
(2) Remove two screws (4).
(3) Remove grip (1) by sliding grip (1) over wire
bundles (5) and (6).
GO TO NEXT PAGE
3
2
1
M04-3750-1A
4
6
5