TM 1-1520-238-23
Change 3
11-1034.1
11.244.
CPG LEFT OR RIGHT DIRECTIONAL CONTROL PEDAL PROTECTIVE COVER
REMOVAL/INSTALLATION continued
11.244.3. Removal
a. Enter CPG station (para 1.56). Observe all
safety precautions.
b. Remove closures (1) and (2) and retainers (3)
and (4).
(1) Remove four nuts (5) and washers (6).
(2) Remove six nuts (7) and washers (8).
c. Remove brushes (9) and (10) from retainers
(3) and (4).
11.244.4. Cleaning
a. Wipe removed and attaching parts with a
clean rag.
11.244.5. Inspection
a. Check removed and attaching parts for
cracks. None allowed.
b. Check removed and attaching parts for dam-
age (para 11.232).
c. Check removed and attaching parts for corro-
sion (para 1.49).
11.244.6. Installation
a. Install brushes (9) and (10) in retainers (3) and
(4).
b. Install retainers (3) and (4) and closures (1)
and (2).
(1) Install six washers (8) and nuts (7) on studs
(11).
(2) Install four washers (6) and nuts (5) on studs
(12).
c. Install scuff plates (para 2.183).
d. Inspect (QA).
END OF TASK
M04-2194-2
1
6
5
10
4
9
7
8
2
3
M04-2194-3
6
5
1
4
9
10
3
2
7
8
11
12