TM 1-1520-238-23
12-48
12.14.
CPG WINDSHIELD WIPER MOTOR REPLACEMENT - continued
b. Attach connector P290 (13) to receptacle
(B5)J1 (14).
c. Install motor (2) and plate (6) on bracket (7).
(1) Position plate (6) on bracket (7).
(2) Install three screws (11) and washers (12) on
plate (6).
(3) Install screw (8), washer (9), and lead (10) on
plate (6).
d. Apply sealing compound on screw (8), washer
(9), and lead (10). Use sealing compound
(item 175, App F) and brush (item 34, App F).
NOTE
To ensure proper installation of flex shaft,
coupling must be installed between flex
shaft and motor fitting.
e. Install flex shaft (1) on motor (2). Torque nut (3)
to 100 INCH-POUNDS.
(1) Remove protective cap (5) from nut (3).
(2) Install coupling (4) and nut (3) on motor (2).
(3) Torque nut (3) to 100 INCH-POUNDS. Use
torque wrench.
(4) Lockwire nut (3) to motor (2). Use wire
(item 229, App F).
GO TO NEXT PAGE
VIEW
ROTATED
M04-970-7
7
6
11
12
10
9
14
13
5
3
1
4
1
3
2
2
8