TM 1-1520-238-23
12-54
SECTION II.
FIRE DETECTION SYSTEM MAINTENANCE
12.16.
FIRE DETECTION SYSTEM INSPECTION
12.16.1. Description
This task covers:
Inspection.
12.16.2. Initial Setup
Tools:
Aircraft mechanics tool kit (item 376, App H)
Personnel Required:
67R
Attack Helicopter Repairer
67R3F
Attack Helicopter Repairer/Technical
Inspector
References:
TM 55-1500-323-24
Equipment Conditions:
Ref
Condition
1.57
Helicopter safed
12.16.3. Inspection
a. Check flame detectors for missing screws and cracked or broken lenses. None allowed.
b. Check louver fire/overheat detector frames for damaged clips. None allowed.
c. Check flame detector amplifiers for damage or loose screws. None allowed.
d. Check APU fire panel for illegible lettering, cracked or broken lenses, and loose knobs or switches.
None allowed.
e. Check connectors for loose or bent pins, thread damage, and for frayed, cut, or loose wires
(TM 55-1500-323-24).
f. Check connector operation for smooth positive locking action (TM 55-1500-323-24).
g. Check general mounting hardware for cracks, gouges, nicks, scratches, chafing, damage, rounded
flats, and stripped or damaged threads. Replace damaged hardware.
h. Check components for scratches, nicks, and gouges.
(1) Minor scratches without burrs or raised material that does not penetrate through protective finish are
acceptable.
(2) Nicks and gouges that exceed 0.040 INCH or 10 percent of material thickness are not allowed.
END OF TASK