TM 1-1520-238-23
12-134
12.41.
FIRE EXTINGUISHER ELECTRONIC MODULE REPLACEMENT - continued
12.41.6. Installation
a. Install module (2) on fire extinguisher (3).
(1) Apply adhesive to module (2) and fire extin-
guisher (3). Use adhesive (item 3, App F).
(2) Position module (2) on fire extinguisher (3).
(3) Clean excess adhesive from fire extinguisher
(3).
(4) Allow adhesive to dry 24 HOURS at ambient
temperature.
b. Pin identified wires (1) in module (2)
(TM 55-1500-323-24).
c. Inspect (QA).
d. Install primary and/or reserve fire extinguish-
er (para 12.39).
END OF TASK
M04-5060-2
1
2
3