TM 1-1520-238-23
Change 3
12-132.1/(12-132.2 blank)
12.40.
FIRE EXTINGUISHER CARTRIDGE REMOVAL/INSTALLATION - continued
NOTE
Some cartridges are fitted with two sizes
of terminals: the ground terminal with a
no. 8 stud and the actuation terminal with
a no. 6 stud. In this case the actuation
wire lug should be replaced with a no. 6
wire lug. If both studs are the same size,
attach wires as removed.
h. Install wire (1) on ground stud (2).
(1) Remove screw (4), washer (5), and shorting
wire (3) from stud (2).
(2) Install screw (4), washer (5), and wire (1) on
stud (2).
(3) Wrap shorting wire (3) around screw (4).
i. Install wire (6) on actuation terminal (7).
(1) Remove nut (8) from terminal (7).
(2) Remove shorting wire (5) from terminal (7).
(3) Install wire (6) on terminal (7).
(4) Install nut (8) on terminal (7).
(5) Wrap shorting wire (1) around terminal (7).
j. Inspect (QA).
k. Install primary and/or reserve fire extinguish-
er (para 12.39).
END OF TASK
3
5
4
2
1
M04-997-7
M04-997-8
6
8
7
1