DASE INTERACTIVE FD/LS CHECK (cont)
42
FD/LS NOGO
DISPLAY
CORRECTIVE ACTION
CPG COLL 2 DCPLR
NOGO CPG
COMPARTMENT
Troubleshoot wiring to isolate
fault (TM 1-1520-238-T-7).
If troubleshooting does not
remove NOGO, replace
CPG collective SPAD switch
S2 (TM 1-1520-238-23).
CPG COLL 1 DCPLR
NOGO CPG
COMPARTMENT
Troubleshoot wiring to isolate
fault (TM 1-1520-238-T-7).
If troubleshooting does not
remove NOGO, replace
CPG collective SPAD switch
S1 ( (TM 1-1520-238-23).
CPG DIR 2 DCPLR
NOGO CPG
COMPARTMENT
Troubleshoot wiring to isolate
fault (TM 1-1520-238-T-7).
If troubleshooting does not
remove NOGO, replace
CPG directional SPAD switch
S2 (TM 1-1520-238-23).
CPG DIR 1 DCPLR
NOGO CPG
COMPARTMENT
Troubleshoot wiring to isolate
fault (TM 1-1520-238-T-7).
If troubleshooting does not
remove NOGO, replace
CPG directional SPAD switch
S1 (TM 1-1520-238-23).
CPG LAT 2 DCPLR
NOGO CPG
COMPARTMENT
Troubleshoot wiring to isolate
fault (TM 1-1520-238-T-7).
If troubleshooting does not
remove NOGO, replace
CPG lateral SPAD switch S2
(TM 1-1520-238-23).
CPG LAT 1 DCPLR
NOGO CPG
COMPARTMENT
Troubleshoot wiring to isolate
fault (TM 1-1520-238-T-7).
If troubleshooting does not
remove NOGO, replace
CPG lateral SPAD switch S1
(TM 1-1520-238-23).