TM 11520238T1
Change 5
417
42
DASE INTERACTIVE FD/LS CHECK (cont)
42
FD/LS NOGO
DISPLAY
CORRECTIVE ACTION
PILOT COLL 1 DCPLR
NOGO PLT
COMPARTMENT
Troubleshoot wiring to isolate
fault (TM 1-1520-238-T-7).
If troubleshooting does not
remove NOGO, replace pilot
collective SPAD switch S1
(TM 1-1520-238-23).
PILOT DIR 2 DCPLR
NOGO PLT
COMPARTMENT
Troubleshoot wiring to isolate
fault (TM 1-1520-238-T-7).
If troubleshooting does not
remove NOGO, replace pilot
directional SPAD switch S2
(TM 1-1520-238-23).
PILOT DIR 1 DCPLR
NOGO PLT
COMPARTMENT
Troubleshoot wiring to isolate
fault (TM 1-1520-238-T-7).
If troubleshooting does not
remove NOGO, replace pilot
directional SPAD switch S1
(TM 1-1520-238-23).
PILOT LAT 2 DCPLR
NOGO PLT
COMPARTMENT
Troubleshoot wiring to isolate
fault (TM 1-1520-238-T-7).
If troubleshooting does not
remove NOGO, replace pilot
lateral SPAD switch S2
(TM 1-1520-238-23).
PILOT LAT 1 DCPLR
NOGO PLT
COMPARTMENT
Troubleshoot wiring to isolate
fault (TM 1-1520-238-T-7).
If troubleshooting does not
remove NOGO, replace pilot
lateral SPAD switch S1
(TM 1-1520-238-23).
PILOT LONG 2 DCPLR
NOGO PLT
COMPARTMENT
Troubleshoot wiring to isolate
fault (TM 1-1520-238-T-7).
If troubleshooting does not
remove NOGO, replace pilot
longitudinal SPAD switch S2
(TM 1-1520-238-23).
PILOT LONG 1 DCPLR
NOGO PLT
COMPARTMENT
Troubleshoot wiring to isolate
fault (TM 1-1520-238-T-7).
If troubleshooting does not
remove NOGO, replace pilot
longitudinal SPAD switch S1
(TM 1-1520-238-23).