TM 11520238T1
414
Change 5
42 DASE INTERACTIVE FD/LS CHECK (cont)
42
TASK
RESULT
y. On DEK, press and
release ENTER
SPACE key (ADC)
or SPC key on the
If one or more FD/LS NO
GO displays listed appear on
HOD, perform the following in
sequence:
CDU (ADD).
(1) Perform SYSTEMS
POWER DOWN
(para 32)
(2) Perform CORRECTIVE
ACTION indicated for first
NOGO displayed on
HOD.
(3) Perform SYSTEMS
POWERUP (para
31).
(4) On DEK, rotate DATA
ENTRY switch to STBY
for 5 seconds, then back
to FD/LS (ADC).
(5) Repeat FD/LS check
beginning with step o. If
NOGO repeats after
CORRECTIVE ACTION,
refer to
TM 1-1520-238-T-7.
z. On pilot HARS
control panel, rotate
HARS switch to
OFF.
NOTE
Record all NOGOs before rotating DATA
ENTRY switch to STBY (ADC).
aa. On DEK, rotate
DATA ENTRY switch
to STBY (ADC).
NOTE
If this FD/LS check is to be followed by the
DASE OPERATIONAL CHECK, omit step 3.
3. Perform SYSTEMS POWER DOWN (para 32), if
power is no longer required.