TM 11520238T1
Change 5
436.3
45A HARS INTERACTIVE FD/LS CHECK
45A
(ADD) (cont)
TASK
RESULT
f. On HARS panel,
rotate HARS switch
to NORM.
If 1 was selected, once the
HARS has started outputting
data, the following message
(prompt) appears:
HARS
TEST IN PROGRESS
If the prompt message
remains for more 90
seconds, the HARS is
NOGO.
If 2 was selected, the
following message (prompt)
appears:
PUT HARS POWER
SWITCH TO OFF THEN
TO NORM
ANY KEY FOR FDLS
MENU
There is no display of HARS
status (NOGOs) when the
test is completed.
NOTE
Once the HARS is turned on, it requires
approximately 6 to 9 minutes for warmup and
inertial alignment.
If FD/LS NOGO display
appears on the HOD, perform
the following in sequence:
(1) Rotate HARS switch to
OFF, then back to
NORM.
(2) If HARS fails the FD/LS
check, perform HARS
SELF CHECK
(TM 11-1520-238-23-2).
(3) If HARS fails
HARS SELF CHECK,
refer to
TM 11-1520-238-23-2 for
troubleshooting
Navigation System.