TM 11520238T1
492
Change 5
413 SYMG INTERACTIVE FD/LS CHECK (cont)
413
TASK
RESULT
NOTE
Record all NOGOs before rotating DATA
ENTRY switch to STBY (ADC).
e. On DEK, rotate
DATA ENTRY switch
to STBY (ADC).
NOTE
If this FD/LS check is to be followed by
SYMBOL GENERATOR OPERATIONAL
CHECK (TM 11-1520-238-23-2), omit step 3.
3. Perform SYSTEMS POWER DOWN (para 32).
FD/LS NOGO
DISPLAY
CORRECTIVE ACTION
SYMBOL
GENERATOR NOGO
LH FAB
Troubleshoot wiring to isolate
fault (TM 11-1520-238-23-2).
If troubleshooting does not
remove NOGO, replace
symbol generator
(TM 11-1520-238-23-1).
END OF TASK