TM 11520238T1
Change 2
495
414 TADS INTERACTIVE FD/LS CHECK (cont)
414
CAUTION
Do not recycle SYSTEM/TADS switch to
TADS immediately after setting
SYSTEM/TADS switch to OFF. Failure to
comply may result in damage to the TADS
power supply.
NOTE
If SYSTEM/TADS switch was set to OFF,
pause 10 seconds before recycling the switch
to TADS.
Pause 60 seconds before proceeding to set
the ACM switch to ACM. PNVS requires 60
seconds for gyro runup before PNVS turret
assembly can be commanded out of the stow
position.
SYSTEM/TADS
TADS
Pilot Station (fig. 21)
PANEL
SWITCH/CONTROL
POSITION
(set to)
FIRE
CONTROL
(fig. 22)
PNVS
PNVS
ACM
ACM
WARNING
Personnel are not allowed closer than 3 feet
from an energized PNVS or TADS system. A
turret assembly rotating under power has
enough force to cause bodily injury.
NOTE
Pause 60 seconds before proceeding to set the
SIGHT SEL switch to TADS. TADS requires 60
seconds for gyro runup before TADS turret
assembly can be commanded out of the stow
position.